Split Line Heat Pumps

Split Line Heat Pumps

Split units are characterised by separate refrigerant module and hydronic module. These units allow heat to be drawn from the outside air while heating the inside environment and vice versa. They are therefore a bivalent, ecological and renewable solution.

The cooling module will be placed on an external wall and floor or roof, while the hydronic module will be properly positioned inside the house. This configuration avoids the risk of ice formation inside the water pipes.

Split Line 4-6 kW

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 4.25 kW
Heating (COP): 5.20 
Cooling (capacity): 4.50 kW
Cooling (EER): 5.55
Net dimensions (split outdoor unit):
1007x712x426 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 6.20 kW
Heating (COP): 5.00 
Cooling (capacity): 6.55 kW
Cooling (EER): 4.90
Net dimensions (split outdoor unit):
1007x712x426 mm
Internal dimensions (indoor unit): 
420x790x270 mm

Split Line 8-10-12-14-16 kW

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 8.30 kW
Heating (COP): 5.20 
Cooling (capacity): 8.40 kW
Cooling (EER): 5.05
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit):
420x790x270 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 10.00 kW
Heating (COP): 5.00 
Cooling (capacity): 10.00 kW
Cooling (EER): 4.80
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95 
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70 
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50 
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Split Line 12-14-16 kW Triphase

Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95 
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70 
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50 
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
420x790x270 mm

Split Line 6 kW with domestic hot water storage

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 6.20 kW
Heating (COP): 5.00 
Cooling (capacity): 6.55 kW
Cooling (EER): 4.90
Net dimensions (split outdoor unit):
1007x712x426 mm
Internal dimensions (indoor unit)
700x1740x770-210 mm

Splits Line 8-10-12-14-16 kW with DHW storage

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 8.30 kW
Heating (COP): 5.20 
Cooling (capacity): 8.40 kW
Cooling (EER): 5.05
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
700x1740x770-210 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 10.00 kW
Heating (COP): 5.00 
Cooling (capacity): 10.00 kW
Cooling (EER): 4.80
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x770-210 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95
Cooling (capacity): 3.10 kW
Cooling (EER): 3.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x770-210 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x770-210 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.50
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x770-210 mm

Split Line 12-14-16 kW triphase with domestic hot water storage

Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95 
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x7770 – 210 mm

Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70 
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit): 
700x1740x770-210 mm

Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50 
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Internal dimensions (indoor unit)
700x1740x770-210 mm

Comfort

3D Air Flow: l’oscillazione verticale e orizzontale dei deflettori consente una distribuzione omogenea dell’aria, o la sua concentrazione nel punto desiderato. Silenzioso: con un livello sonoro di soli 20dB,  il climatizzatore Dynamic garantisce silenziosità e tranquillità. Follow Me: quest’innovativa funzione fa sì che il climatizzatore moduli la propria potenza in base alla temperatura rilevata dal sensore all’interno del telecomando. In tal modo ci si può muovere all’interno della casa senza preoccuparsi di modificare le impostazioni del clima, che assicurerà sempre il massimo comfort e il minor consumo di energia in base alla nostra posizione.

Efficienza energetica

A+++: il massimo dell’efficienza al servizio della tua casa.

Alte Prestazioni COP (Coefficient Of Performance): tutti i modelli della linea Dynamic garantiscono un’eccellente resa termica per kW in modalità riscaldamento.

Incentivi Fiscali

Con l’acquisto di uno o più condizionatori ad alta efficienza Haier puoi usufruire di bonus e incentivi fiscali che garantiscono il rimborso di tutto o di una parte dell’importo speso.

Wi-fi included
Wide operating range
Multifunctional controller with backlit display for remote control
Temperature sensor for DHW cylinder as standard
Cooling / Heating / DHW
Smart Grid function for integration and management with the solar system