Split PDCs
Split units are characterized by separate refrigerant module and hydronic module. Such units make it possible to draw heat from the outdoor air while heating the indoor environment and vice versa. They are thus a bivalent, environmentally friendly and renewable solution.
The refrigerant module will be placed on the exterior wall and floor or roof, while the hydronic module will be properly placed inside the house. This configuration avoids the risk of ice formation inside the water pipes.
Split 4-6 kW
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 4.25 kW
Heating (COP): 5.20
Cooling (capacity): 4.50 kW
Cooling (EER): 5.55
Net dimensions (split outdoor unit):
1007x712x426 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 6.20 kW
Heating (COP): 5.00
Cooling (capacity): 6.55 kW
Cooling (EER): 4.90
Net dimensions (split outdoor unit):
1007x712x426 mm
Indoor size (indoor unit):
420x790x270 mm
Split 8-10-12-14-16 kW
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 8.30 kW
Heating (COP): 5.20
Cooling (capacity): 8.40 kW
Cooling (EER): 5.05
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 10.00 kW
Heating (COP): 5.00
Cooling (capacity): 10.00 kW
Cooling (EER): 4.80
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Split 12-14-16 kW three-phase
Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
420x790x270 mm
Split 6 kW with sanitary storage
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 6.20 kW
Heating (COP): 5.00
Cooling (capacity): 6.55 kW
Cooling (EER): 4.90
Net dimensions (split outdoor unit):
1007x712x426 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Split 8-10-12-14-16 kW
with sanitary storage
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 8.30 kW
Heating (COP): 5.20
Cooling (capacity): 8.40 kW
Cooling (EER): 5.05
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 10.00 kW
Heating (COP): 5.00
Cooling (capacity): 10.00 kW
Cooling (EER): 4.80
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95
Cooling (capacity): 3.10 kW
Cooling (EER): 3.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.50
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Split 12-14-16 kW three-phase
with sanitary storage
Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 12.1 kW
Heating (COP): 4.95
Cooling (capacity): 12.00 kW
Cooling (EER): 4.00
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x7770 – 210 mm
Power supply: 380-415/3/50 V/Ph/Hz
Heating (capacity): 14.5 kW
Heating (COP): 4.70
Cooling (capacity): 13.50 kW
Cooling (EER): 3.61
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Power supply: 220-240/1/50 V/Ph/Hz
Heating (capacity): 16.0 kW
Heating (COP): 4.50
Cooling (capacity): 14.90 kW
Cooling (EER): 3.40
Net dimensions (split outdoor unit):
1118x864x523 mm
Indoor size (indoor unit):
700x1740x770-210 mm
Comfort
Energy Efficiency
A+++: the ultimate in efficiency at the service of your home.
High Performance COP (Coefficient Of Performance): all models in the Dynamic line provide excellent heat output per kW in heating mode.
Tax Incentives
With the purchase of one or more Haier high-efficiency air conditioners, you can take advantage of tax bonuses and incentives that guarantee a refund of all or part of the amount spent.